Application Type:Indoor
Ventilation Type:Static plate, heat and humidity transfer
Typical Airflow Range:200-540 CFM
AHRI 1060 Certified Core:One L85-G5
OA Filter(s):Total Qty. 1, MERV 8: 14" x 20" x 2"
RA Filter(s):Total Qty. 1, MERV 8: 14" x 20" x 2"
Unit Dimensions & Weight:54 1/2" L x 16 3/8" W x 36 3/4" H, 137-199 lbs. (varies by option)
Electrical Service
[11] 120V / 1 Phase / 60 HZ
[15] 208-230V / 1 Phase / 60 HZ
[19] 277V / 1 Phase / 60 HZ
[35] 208-230V / 3 Phase / 60 HZ
[34] 460V / 3 Phase / 60 HZ
EA/FA Fan Motor
Fixed Speed / ODP / PSC - Direct Drive (Standard)
[E] Variable Speed / ECM - Direct Drive Motors
Fan Control
[A] Single Contactor For Common Fan Control (Standard)
[G] Terminal Strip For EC Motors
Disconnect
[N] Non-fused (Standard)
[F] Fused
Control Options
[T] Standard Unit Control Wiring
Integrated Programmable Controls - Enhanced 
Integrated Programmable Controls - Premium
Filter Type
Merv 8 (Standard)
Wall
[S] Single (Standard)
[D] Double
Paint
[W] White Paint
[C] Custom Paint
Filter Monitor
[F] Filter Monitor Both Airstreams
Dampers
Backdraft Damper, EV450, P/N 102402 10", BD10
Controls
Digital Time Clock, EV450, HE, LE, RD, P/N 131300 Wall Mount, TC7D-W
Digital Time Clock, EV450, HE, LE, RD, P/N 131301 Exterior Enclosure, TC7D-E
CO2 Sensor, EV450, HE, LE, RD, P/N 131304 Room Mount, CO2-W
CO2 Sensor, EV450, HE, LE, RD, P/N 131305 Duct Mount, CO2-D
IAQ Sensor, EV450, HE, LE, RD, P/N 131308 Room Mount, IAQ-W
IAQ Wiring Supplement (PDF) | PDF (1,023KB)
IAQ Sensor, EV450, HE, LE, RD, P/N 131307 Duct Mount, IAQ-D
IAQ Wiring Supplement (PDF) | PDF (1,023KB)
Occupancy Sensor, EV450, HE, LE, RD, P/N 131302 Ceiling Mount, MC-C
Occupancy Sensor, EV450, HE, LE, RD, P/N 131303 Wall Mount, MC-W
Smoke Detector, EV450, HE, LE, RD, P/N 102396 Duct Mount, SD-D
Remote Display, EV450, HE, LE, RD with Enhanced or Premium Controls, P/N 131311 Handheld/Wall Mount RD-M  
Room Pressure Sensor with Display, EV450, HE, LE, RD with Premium Controls, P/N 131314, RPS-WD  
Room Pressure Sensor without Display, EV450, HE, LE, RD with Premium Controls, P/N 131310, RPS-WOD  
Duct Static Pressure Sensor with Display, EV450, HE, LE, RD with Premium Controls, P/N 131315, DPS-WD  
Duct Static Pressure Sensor without Display, EV450, HE, LE, RD with Premium Controls, P/N 131309, DPS-WOD  
Temperature Sensor Kit, EV450, HE, LE, RD with Premium Controls for non-integrated heating, P/N 131318, TS  
Solid State Speed Control Kit, EV450, P/N 102380 115V
Solid State Speed Control Kit, EV450, P/N 102381 208-230V
Potentiometer Speed Control, EV450, HE1X-1.5X, P/N 147050 Remote Installed for ECM, SCECM
Duct Transitions and Adapters
Transition Kit, EV450IN, P/N 134712 10" Round, 2 transitions 45EVT10
Flange Kit, EV450IN, P/N 134714 Rectangular 12" x 8", 2 flanges 45EVDF
Filters
Filter, EV450, HE1.5, RD, HE-2XRTC, P/N 990080 Merv 8 14"x20"x2" Single Filter
Filter, EV450, HE1.5, RD, HE-2XRTC, P/N 990300 Merv 13 14"x20"x2" Single Filter
Mounting
Hanging Bracket Kit, EV450IN, P/N 134713  
Vibration Isolation Kit, EV450IN, P/N 102395
Wall Caps and Louvers
Wall Cap, EV450, P/N 102407 10" Galvanized, FA10-G
Wall Cap, EV450, P/N 102410 10" Paintable Galvanneal, FA10-P
Louver, EV450IN, P/N 102413 10" Round Duct Connection - 12" (W) x 12" (H), VW12 X 12-G
Heaters & Furnaces
EV450IN CSI
EV450IN_pdf | PDF (106KB)
EV450IN_doc | Word Doc (38KB)