Application Type:Indoor
Ventilation Type:Static plate, heat and humidity transfer
Typical Airflow Range:500-2,200 CFM
AHRI 1060 Certified Core:Two L125-G5
OA Filter(s):Total Qty. 2, MERV 8: 20" x 20" x 2"
RA Filter(s):Total Qty. 3, (2) MERV 8: 20" x 20" x 2" and (1) 20" x 14" x 2"
Dimensions:92 1/4" L x 57 3/4" W x 51" H
Weight:1,035-1,303 lbs. (varies by option)
Installation Location
[IN] Indoor Unit
Orientation
A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

R

Electrical Service
[15] 208-230V / 1 Phase / 60 Hz
[35] 208-230V / 3 Phase / 60 Hz
[34] 460V / 3 Phase / 60 Hz
[38] 575V / 3 Phase / 60 Hz
Supply Air Motor
[V] TEFC Direct Drive - 2HP
Exhaust Air Motor
[V] TEFC Direct Drive - 2HP
Controls
[-] Standard Unit Control Wiring
Integrated Programmable Controls - Premium
BACnet Factory Activation Available
Disconnect
[N] Non-fused (Standard)
[F] Fused
Coil Type
[DX] DX Coil - 1 Circuit
[DU] DX Coil - 2 Circuit
[CW] Chilled Water Coil
[XS] Heat Pump Coil - 1 Circuit
[XB] Heat Pump Coil - 2 Circuit
[XH] DX Coil + Hot Water Coil - 1 Circuit
[DH] DX Coil + Hot Water Coil - 2 Circuit
[CH] Hot Water Coil + Chilled Water Coil
[SC] Coil for Hot Water & Chilled Water
[HW] Hot Water
[-] No Coil or Field Installed​
Filter Type
MERV 8 (Standard)
Filter Monitor
[-] None
[F] Filter Monitor Both Airstreams
Wall
[S] Single (Standard)
[D] Double
Paint
[-] None
[W] White Paint
[C] Custom Paint
Controls
Digital Time Clock, SL, EV, EV Premium, HE, LE, RD, P/N 131300
Wall Mount, TC7D-W
Digital Time Clock, SL, EV, EV Premium, HE, LE, RD, P/N 131301
Exterior Enclosure, TC7D-E
Occupancy Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131302
Ceiling Mount, MC-C
Occupancy Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131303
Wall Mount, MC-W
CO2 Sensor, SL, EV Premium, HE, LE, RD, DN, P/N 131304
Wall Mount, CO2-W
CO2 Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131305
Duct Mount, CO2-D
IAQ Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131307
Duct Mount, IAQ-D
IAQ Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131308
Wall Mount, IAQ-W
Smoke Detector, HE, LE, RD, DN, P/N 102396
Duct Mount, SD-D
Remote Display, HE, LE, RD, DN, P/N 131311
Units with Enhanced or Premium Controls, Handheld/Wall Mount RD-M
Room Pressure Sensor, HE, LE, RD, DN, P/N 131314
Sensor with Display, Units with Premium Controls, RPS-WD 
Room Pressure Sensor, HE, LE, RD, DN, P/N 131310
Sensor without Display, Units with Premium Controls, RPS-WOD 
Duct Static Pressure Sensor, HE, LE, RD, DN, P/N 131315
Sensor with Display, Units with Premium Controls, DPS-WD 
Duct Static Pressure Sensor, HE, LE, RD, DN, P/N 131309
Sensor without Display, Units with Premium Controls, DPS-WOD 
Temperature Sensor Kit, HE, LE, RD, DN, P/N 131318
Units with Premium Controls for non-integrated heating, TS 
BACNet License Field Request, HE, LE, RD with Enhanced or Premium Controls, P/N 131316  
Filters
Filter, HE07 HE1.5, RD, HE-2XRTC, P/N 990080 
MERV 8 14"x20"x2" Single Filter
Filter, HE07, HE1.5, RD, HE-2XRTC, P/N 990091
MERV 8 14"x20"x2" Case of 12
Filter, HE07, HE1.5, RD, HE-2XRTC, P/N 990300
MERV 13 14"x20"x2" Single Filter
Filter, HE, CA, PA, RD, DN-3, P/N 990083
MERV 8 20"x20"x2" Single Filter
Filter, HE, CA, PA, RD, DN-3,  P/N 990084
MERV 8 20"x20"x2" Case of 12
Filter, HE, CA, PA, RD, DN-3, P/N 990303
MERV 13 20"x20"x2" Single Filter
Filter Set, RD2X, P/N 990420
MERV 8
RD2XIN CSI
RD2XIN | PDF (123KB)
RD2XIN | Word Doc (53KB)
Gas Furnace CSI
Static Gas Furnace CSI | PDF (196KB)
Static Gas Furnace CSI | Word Doc (22KB)
Electric Duct Heater CSI