Application Type:Rooftop
Ventilation Type:Static plate, heat and humidity transfer
Typical Airflow Range:500-1,700 CFM
AHRI 1060 Certified Core:Two L125-G5
OA Filter(s):Total Qty. 2, MERV 8: 14" x 20" x 2"
RA Filter(s):Total Qty. 2, MERV 8: 20" x 20" x 2"
Weight:566-711 lbs. (varies by option)
Orientation
C
Installation Location
[RT] Outdoor Unit
Electrical Service
[15] 208-230V / 1 Phase / 60 Hz
[35] 208-230V / 3 Phase / 60 Hz
[34] 460V / 3 Phase / 60 Hz
[38] 575V / 3 Phase / 60 Hz
Fan Control
[A] Motor Starters & Contactors (Standard)​
[V] Onboard VFD Both Airstreams
Shaft Grounding Ring(s)
No (Standard)
EA and FA Motors
Fresh Air Motor
[V] TEFC Belt Drive - 2 HP
Exhaust Air Motor
[V] TEFC Belt Drive - 2 HP
Controls
[T] Standard Unit Control Wiring - 24 VAC Transformer/Relay Package
Integrated Programmable Controls - Enhanced 
Integrated Programmable Controls - Premium
BACnet Factory Activation Available on Enhanced or Premium Packages
Cross-core Differential Pressure Ports
Disconnect
[N] Non-fused (Standard)
[F] Fused
Isolation Dampers
[-] No Dampers (Standard)
Filter Type
MERV 8 (Standard)
Filter Monitor
[-] None
[F] Filter Monitor Both Airstreams
Wall
[S] Single (Standard)
[D] Double
Paint
[-] None
[W] White Paint
[C] Custom Paint
Unit Controls
Digital Time Clock, SL, EV, EV Premium, HE, LE, RD, P/N 131300 Wall Mount, TC7D-W
Digital Time Clock, SL, EV, EV Premium, HE, LE, RD, P/N 131301 Exterior Enclosure, TC7D-E
Occupancy Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131302 Ceiling Mount, MC-C
Occupancy Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131303 Wall Mount, MC-W
CO2 Sensor, SL, EV Premium, EV450, HE, LE, RD, DN, P/N 131304 Wall Mount, CO2-W
CO2 Sensor, EV, EV Premium, HE, LE, RD, DN, P/N 131305 Duct Mount, CO2-D
IAQ Sensor, EV, EV Premium, HE, LE, RD, DN, P/N 131307 Duct Mount, IAQ-D
IAQ Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131308 Wall Mount, IAQ-W
Smoke Detector, EV450, HE, LE, RD, DN, P/N 102396 Duct Mount, SD-D
Remote Display, EV450, HE, LE, RD, DN, P/N 131311 Units with Enhanced or Premium Controls, Handheld/Wall Mount RD-M
Room Pressure Sensor, EV450, HE, LE, RD, DN, P/N 131314 Sensor with Display, Units with Premium Controls, RPS-WD 
Room Pressure Sensor, EV450, HE, LE, RD, DN, P/N 131310 Sensor without Display, Units with Premium Controls, RPS-WOD 
Duct Static Pressure Sensor, EV450, HE, LE, RD, DN, P/N 131315 Sensor with Display, Units with Premium Controls, DPS-WD 
Duct Static Pressure Sensor, EV450, HE, LE, RD, DN, P/N 131309 Sensor without Display, Units with Premium Controls, DPS-WOD 
Temperature Sensor Kit, EV450, HE, LE, RD, DN, P/N 131318 Units with Premium Controls for non-integrated heating, TS 
Heaters & Furnaces
Electric Duct Heater - RH Series (1-11.5 kW)
Indirect Gas-fired Duct Furnace - GH Series (50-125 MBH)
Electric Duct Heater - EK Series (1-25 kW)
Filters
Filter, EV450, HE1.5, RD, HE-2XRTC, P/N 990080 MERV 8 14"x20"x2" Single Filter
Filter, EV450, HE1.5, RD, HE-2XRTC, P/N 990091 MERV 8 14"x20"x2" Case of 12
Filter, EV450, HE1.5, RD, HE-2XRTC, P/N 990300 MERV 13 14"x20"x2" Single Filter
Filter, HE, CA, PA, RD, DN-3, P/N 990083 MERV 8 20"x20"x2" Single Filter
Filter, HE, CA, PA, RD, DN-3,  P/N 990084 MERV 8 20"x20"x2" Case of 12
Filter, HE, CA, PA, RD, DN-3, P/N 990303 MERV 13 20"x20"x2" Single Filter
Filter, HE-2XRTC, DN-2RT, P/N 990227 20"x28"x3/8", Filter for Hood for HE2XRTC, Filter for Mist Eliminator Option for DN-2RT
Duct Transitions and Adapters
RTC Transition Kit - For Vertical RTU, For Horizontal RTU
HE2XRT CSI
HE2XRT_pdf | PDF (113KB)
HE2XRT_doc | Word Doc (43KB)