Application Type:Rooftop
Ventilation Type:Static plate, heat and humidity transfer
Typical Airflow Range:375-1,650 CFM
AHRI 1060 Certified Core:One L62-G5, One L125-G5
OA Filter(s):Total Qty. 2, MERV 8: 16" x 20" x 2"
RA Filter(s):Total Qty. 2, MERV 8: 16" x 20" x 2"
Unit Dimensions & Weight:1" Cabinets - 189 3/8" L x 76 3/4" W x 76 3/4" H, 2450-3150 lbs.; 2" Cabinets - 191 3/8" L x 78 3/4" W x 77 3/4" H, 2550-3275 lbs.
Orientation
F
H
R
V
Electrical Service
[13] 208V / 1 Phase / 60HZ
[15] 230V / 1 Phase / 60 HZ
[33] 208V / 3 Phase / 60 HZ
[35] 230V / 3 Phase / 60 HZ
[34] 460V / 3 Phase / 60 HZ
[38] 575V / 3 Phase / 60 HZ
Vibration Isolation
Neoprene Isolators (Standard)
Spring Isolators
BACNet Factory Activation
[4] Available
Paint
None (Standard)
2500 Hour Salt Spray
Drain Overflow Switch
Available
Mist Eliminator
Available
Fan Control
[E] ECM
[V] VFD
Unit Fusing
[N] Non-fused (Standard)
[F] Fused
SA Fan Location
[B] Before Coil, Blow-thru (Standard)
[A] After Coil, Draw-thru
GFCI Convenience Outlet
Available
Cooling
[D] Direct Expansion Coil
[R] Direct Expansion & Hot Gas Reheat Coils
Heating
[-] None
[E] Electric Heater
[G] Gas Heat Module
[S] Steam Coil
[H] Hot Water Coil
Packaged Refrigeration
[P] Packaged Refrigeration
Insulation
[1] 1" Insulation (Standard)
[2] 2" Insulation
Recirculation Damper
Available
Controls
Room Temperature and Humidity Sensor, DN, P/N 102397 Wall Mount, RTH-W
CO2 Sensor, SL, EV Premium, EV450, HE, LE, RD, DN, P/N 131304 Wall Mount, CO2-W
CO2 Sensor, EV, EV Premium, HE, LE, RD, DN, P/N 131305 Duct Mount, CO2-D
IAQ Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131308 Wall Mount, IAQ-W
IAQ Sensor, EV, EV Premium, HE, LE, RD, DN, P/N 131307 Duct Mount, IAQ-D
Occupancy Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131302 Ceiling Mount, MC-C
Occupancy Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131303 Wall Mount, MC-W
Smoke Detector, EV450, HE, LE, RD, DN P/N 102396 Duct Mount, SD-D
Remote Display, EV450, HE, LE, RD, DN with Enhanced or Premium Controls, P/N 131311 Handheld/Wall Mount RD-M 
Room Pressure Sensor with Display, EV450, HE, LE, RD, DN with Premium Controls, P/N 131314, RPS-WD 
Room Pressure Sensor without Display, EV450, HE, LE, RD, DN with Premium Controls, P/N 131310, RPS-WOD 
Duct Static Pressure Sensor with Display, EV450, HE, LE, RD, DN with Premium Controls, P/N 131315, DPS-WD 
Duct Static Pressure Sensor without Display, EV450, HE, LE, RD, DN with Premium Controls, P/N 131309, DPS-WOD 
Temperature Sensor Kit, EV450, HE, LE, RD, DN with Premium Controls for non-integrated heating, P/N 131318, TS 
Roof Curbs
Roof Curb, DN-2RT, P/N 109177 Standard 14", ERV + Cooling or Heating
Roof Curb, DN-2RT, P/N 109176 Standard 14", ERV + Cooling + Heating
Curb Clip Kits
Curb Clip Kit, DN-2RT, P/N 109169 ERV or ERV + Cooling or Heating, 1" Cabinet
Curb Clip Kit, DN-2RT, P/N 109168 ERV + Cooling + Heating, 1" Cabinet
Curb Clip Kit, DN-2RT, P/N 168100 ERV or ERV + Cooling or Heating, 2" Cabinet
Curb Clip Kit, DN-2RT, P/N 168101 ERV or ERV + Cooling + Heating, 2" Cabinet
Filters
Filter, HE1.5, HE-4XRTC, DN-2, DN-5, P/N 990229 MERV 8 16"x20"x2" Single Filter
Filter, HE1.5, HE-4XRTC, DN-2, DN-5, P/N 990301 MERV 13 16"x20"x2" Single Filter
Filter, DN-2, DN-5, P/N 990685 MERV 13 16"x20"x4" Single Filter
Filter, DN-2, DN-5, P/N 990687 MERV 14 16"x20"x2" Single Filter
Filter, DN-2, DN-5, P/N 990689 MERV 14 16"x20"x4" Single Filter
Filter, HE-2XRTC, DN-2RT, P/N 990227 20"x28"x3/8", Filter for Hood for HE2XRTC, Filter for Mist Eliminator Option for DN-2RT
Coil Accessories
Waterless Trap, DN, P/N 102387 Positive Pressure, WT-P
Waterless Trap, DN, P/N 102386 Negative Pressure, WT-N
DN Series CSI
DN-CSI_PDF | PDF (440KB)
DN-CSI_DOC | File (313KB)
DN Series Brochure

Dedicated outdoor air units with energy recovery