Application Type:Rooftop
Ventilation Type:Static plate, heat and humidity transfer
Typical Airflow Range:1,100-2,400 CFM
AHRI 1060 Certified Core:Three L125-G5
OA Filter(s):Total Qty. 2, MERV 8: 16" x 25" x 2"
RA Filter(s):Total Qty. 3, MERV 8: 20" x 20" x 2"
Unit Dimensions & Weight:81 1/4" L x 63 1/2" W x 48 1/4" H, 713-1,084 lbs. (varies by option)
Electrical Service
[15] 208-230V / 1 Phase / 60 HZ
[35] 208-230V / 3 Phase / 60 HZ
[34] 460V / 3 Phase / 60 HZ
[38] 575V / 3 Phase / 60 HZ
Fresh Air Motor
[W] TEFC Belt Drive - 3 HP
Exhaust Air Motor
[W] TEFC Belt Drive - 3 HP
Fan Control
[A] Motor Starters & Contactors (Standard)​
[V] Onboard VFD Both Airstreams
[F] Onboard VFD FA / Motor Starter & Contactor EA
[E] Onboard VFD EA / Motor Starter & Contactor FA
Disconnect
[N] Non-fused (Standard)
[F] Fused
Control Options
[T] Standard Unit Control Wiring
Integrated Programmable Controls - Enhanced 
Integrated Programmable Controls - Premium
Filter Type
Merv 8 (Standard)
Wall
[S] Single (Standard)
[D] Double
Paint
[W] White Paint
[C] Custom Paint
Filter Monitor
[F] Filter Monitor Both Airstreams
Controls
Digital Time Clock, SL, EV450, HE, LE, RD, P/N 131300Wall Mount, TC7D-W
Digital Time Clock, SL, EV450, HE, LE, RD, P/N 131301Exterior Enclosure, TC7D-E
CO2 Sensor, SL, EV450, HE, LE, RD, DN P/N 131304Room Mount, CO2-W
CO2 Sensor, EV450, HE, LE, RD, DN P/N 131305Duct Mount, CO2-D
IAQ Sensor, SL, EV450, HE, LE, RD, DN P/N 131308Room Mount, IAQ-W
IAQ Wiring Supplement (PDF) | PDF (1,023KB)
IAQ Sensor, EV450, HE, LE, RD, DN P/N 131307Duct Mount, IAQ-D
IAQ Wiring Supplement (PDF) | PDF (1,023KB)
Occupancy Sensor, SL, EV450, HE, LE, RD, DN P/N 131302Ceiling Mount, MC-C
Occupancy Sensor, SL, EV450, HE, LE, RD, DN P/N 131303Wall Mount, MC-W
Smoke Detector, EV450, HE, LE, RD, DN P/N 102396Duct Mount, SD-D
Remote Display, EV450, HE, LE, RD, DN with Enhanced or Premium Controls, P/N 131311 Handheld/Wall Mount RD-M 
Room Pressure Sensor with Display, EV450, HE, LE, RD, DN with Premium Controls, P/N 131314, RPS-WD 
Room Pressure Sensor without Display, EV450, HE, LE, RD, DN with Premium Controls, P/N 131310, RPS-WOD 
Duct Static Pressure Sensor with Display, EV450, HE, LE, RD, DN with Premium Controls, P/N 131315, DPS-WD 
Duct Static Pressure Sensor without Display, EV450, HE, LE, RD, DN with Premium Controls, P/N 131309, DPS-WOD 
Temperature Sensor Kit, EV450, HE, LE, RD, DN with Premium Controls for non-integrated heating, P/N 131318, TS 
Filters
Filter, HE-3XRTC, P/N 990081 Merv 8 16"x25"x2" Single Filter
Filter, HE-3XRTC, P/N 990302 Merv 13 16"x25"x2" Single Filter
Filter, HE, LE, CA, PA, RD, P/N 990083 Merv 8 20"x20"x2" Single Filter
Filter, HE, LE, CA, PA, RD, DN3 P/N 990303Merv 13 20"x20"x2" Single Filter
Sound Barriers
Sound Absorbing Barrier, HE-3X-LE10X, P/N SB4X10 4' x 10'
Sound Absorbing Barrier, HE-3X-LE10X, SB4X20 4' X 20'
Sound Absorbing Barrier, HE-3X-LE10X, SB4X30 4' X 30'
Nylon Ties, HE-3X-LE10X,  P/N SBBAND 60"- Qty. 10
Barrier Tape, HE-3X-LE10X, P/N SBTAPE 165' x 1 7/8"
Heaters & Furnaces
GHIN Indirect Gas-Fired Duct Furnace
Static Gas Furnace CSI | PDF (196KB)
Static Gas Furnace CSI | Word Doc (22KB)
GHRT Indirect Gas-Fired Duct Furnace
Static Gas Furnace CSI | PDF (196KB)
Static Gas Furnace CSI | Word Doc (22KB)
EK Series Electric Duct Heaters

EH series heaters are no longer available effectively immediately. All attributes and capacities of EH Heaters will be available with EK series.

RTC Transition Kit
HE3XRTC Transition Kits Available
HE3XRT CSI
HE3XRT_pdf | File (113KB)
HE3XRT_doc | File (43KB)