Application Type:Rooftop
Ventilation Type:Static plate, heat and humidity transfer
Typical Airflow Range:750-3,300 CFM
AHRI 1060 Certified Core:Three L125-G5
OA Filter(s):Total Qty. 3, MERV 8: 20" x 20" x 2"
RA Filter(s):Total Qty. 3, MERV 8: 20" x 20" x 2"
Unit Dimensions & Weight:94" L x 63 1/4" W x 44" H, 656-972 lbs. (varies by option)
Orientation
F
H
R
V
Electrical Service
[11] 120V / 1 Phase / 60 HZ
[15] 208-230V / 1 Phase / 60 HZ
[35] 208-230V / 3 Phase / 60 HZ
[34] 460V / 3 Phase / 60 HZ
[38] 575V / 3 Phase / 60 HZ
Fresh Air Motor
[V] TEFC Belt Drive - 2 HP
[W] TEFC Belt Drive - 3 HP
[X] TEFC Belt Drive - 5 HP
Exhaust Air Motor
[V] TEFC Belt Drive - 2 HP
[W] TEFC Belt Drive - 3 HP
[X] TEFC Belt Drive - 5 HP
Fan Control
[A] Motor Starters & Contactors (Standard)​
[V] Onboard VFD Both Airstreams
[F] Onboard VFD FA / Motor Starter & Contactor EA
[E] Onboard VFD EA / Motor Starter & Contactor FA
Disconnect
[N] Non-fused (Standard)
[F] Fused
Control Options
[T] Standard Unit Control Wiring
Integrated Programmable Controls - Enhanced 
Integrated Programmable Controls - Premium
Isolation Dampers
[D] Motorized Dampers Both Airstreams
[E] Motorized Damper EA Airstream
[F] Motorized Damper FA/OA Airstream
Filter Type
Merv 8 (Standard)
Wall
[S] Single (Standard)
[D] Double
Paint
[W] White Paint
[C] Custom Paint
Filter Monitor
[F] Filter Monitor Both Airstreams
Combo Curbs
Engineered Combo Curb, HE-3X, P/N 102906 Trane ECTPCD3X
Engineered Combo Curb, HE-3X, P/N 102910 Trane ECTPE3X
Engineered Combo Curb, HE-3X, P/N 102914 Trane ECTVB3X
Engineered Combo Curb, HE-3X, P/N 102922 Trane ECTVC3X
Engineered Combo Curb, HE-3X, P/N 102956 Carrier ECCWG3X 
Engineered Combo Curb, HE-3X, P/N 102962 Carrier ECCWH3X 
Engineered Combo Curb, HE-3X, P/N 102968 Carrier ECCWI3X 
Engineered Combo Curb, HE-3X, P/N 102976 Carrier ECCWJ3X 
Engineered Combo Curb, HE-3X, P/N 102984 Carrier ECCWK3X 
Controls
Digital Time Clock, EV450, HE, LE, RD, P/N 131300 Wall Mount, TC7D-W
Digital Time Clock, EV450, HE, LE, RD, P/N 131301 Exterior Enclosure, TC7D-E
CO2 Sensor, EV450, HE, LE, RD, P/N 131304 Room Mount, CO2-W
CO2 Sensor, EV450, HE, LE, RD, P/N 131305 Duct Mount, CO2-D
IAQ Sensor, EV450, HE, LE, RD, P/N 131308 Room Mount, IAQ-W
IAQ Wiring Supplement (PDF) | PDF (1,023KB)
IAQ Sensor, EV450, HE, LE, RD, P/N 131307 Duct Mount, IAQ-D
IAQ Wiring Supplement (PDF) | PDF (1,023KB)
Occupancy Sensor, EV450, HE, LE, RD, P/N 131302 Ceiling Mount, MC-C
Occupancy Sensor, EV450, HE, LE, RD, P/N 131303 Wall Mount, MC-W
Smoke Detector, EV450, HE, LE, RD, P/N 102396 Duct Mount, SD-D
Remote Display, EV450, HE, LE, RD with Enhanced or Premium Controls, P/N 131311 Handheld/Wall Mount RD-M  
Room Pressure Sensor with Display, EV450, HE, LE, RD with Premium Controls, P/N 131314, RPS-WD  
Room Pressure Sensor without Display, EV450, HE, LE, RD with Premium Controls, P/N 131310, RPS-WOD  
Duct Static Pressure Sensor with Display, EV450, HE, LE, RD with Premium Controls, P/N 131315, DPS-WD  
Duct Static Pressure Sensor without Display, EV450, HE, LE, RD with Premium Controls, P/N 131309, DPS-WOD  
Temperature Sensor Kit, EV450, HE, LE, RD with Premium Controls for non-integrated heating, P/N 131318, TS  
Curbs
Curb Wind Clip, HE-3XRT, P/N 3XHECC  
Curb Clip Manual (PDF) | PDF (446KB)
Roof Curb, HE-3XRT, P/N 135614 Standard 14"
Filters
Filter, HE, LE, CA, PA, RD, P/N 990083 Merv 8 20"x20"x2" Single Filter
Filter, HE, LE, CA, PA, RD, P/N 990303 Merv 13 20"x20"x2" Single Filter
Sound Barriers
Sound Absorbing Barrier, HE-3X-LE10X, P/N SB4X10 4' x 10'
Sound Absorbing Barrier, HE-3X-LE10X, SB4X20 4' X 20'
Sound Absorbing Barrier, HE-3X-LE10X, SB4X30 4' X 30'
Nylon Ties, HE-3X-LE10X,  P/N SBBAND 60"- Qty. 10
Barrier Tape, HE-3X-LE10X, P/N SBTAPE 165' x 1 7/8"
Heaters & Furnaces
HE3XRT CSI
HE3XRT_pdf | File (112KB)
HE3XRT_doc | File (43KB)