Application Type:Indoor
Ventilation Type:Static plate, heat and humidity transfer
Typical Airflow Range:375-1,575 CFM
AHRI 1060 Certified Core:One L62-G5, One L125-G5
OA Filter(s):Total Qty. 2, MERV 8: 14" x 20" x 2" and 16" x 20" x 2"
RA Filter(s):Total Qty. 2, MERV 8: 14" x 20" x 2" and 16" x 20" x 2"
Unit Dimensions & Weight:59 1/2" L x 34 1/2" W x 46 1/4" H, 337-504 lbs. (varies by option)
Electrical Service
[11] 120V / 1 Phase / 60 HZ
[15] 208-230V / 1 Phase / 60 HZ
[19] 277V / 1 Phase / 60 HZ
[35] 208-230V / 3 Phase / 60 HZ
[34] 460V / 3 Phase / 60 HZ
Fresh Air Motor
[E] ECM - Direct Drive Motorized Impeller​
[S] TEFC - Direct Drive Motorized Impeller (Standard)
Exhaust Air Motor
[S] TEFC - Direct Drive Motorized Impeller (Standard)
[E] ECM - Direct Drive Motorized Impeller​
Fan Control
[A] Single Contactor For Common Fan Control (Standard)
[D] Dual Contactors For Independent Blower Controls
[G] Terminal Strip For EC Motors
Disconnect
[N] Non-fused (Standard)
[F] Fused
Control Options
[T] Standard Unit Control Wiring
Integrated Programmable Controls - Enhanced 
Integrated Programmable Controls - Premium
Economizer/Bypass Damper
No Bypass (Standard)
Bypass
Bypass Controls
Dry Bulb
Enthalpic
Isolation Dampers
[D] Motorized Dampers Both Airstreams
[E] Motorized Damper EA Airstream
[F] Motorized Damper FA/OA Airstream
[B] Backdraft Damper Both Airstreams
[R] Backdraft Damper EA Airstream
[S] Backdraft Damper OA Airstream
[T] Motorized Damper OA, Backdraft Damper EA​
Filter Type
Merv 8 (Standard)
Wall
[S] Single (Standard)
[D] Double
Paint
[W] White Paint
[C] Custom Paint
Filter Monitor
[F] Filter Monitor Both Airstreams
Dampers
Backdraft Damper, HE1.5IN, P/N 148031 Outside Airstream
Backdraft Damper, HE1.5IN, P/N 148032 Exhaust Airstream
Controls
Digital Time Clock, EV450, HE, LE, RD, P/N 131300 Wall Mount, TC7D-W
Digital Time Clock, EV450, HE, LE, RD, P/N 131301 Exterior Enclosure, TC7D-E
CO2 Sensor, EV450, HE, LE, RD, P/N 131304 Room Mount, CO2-W
CO2 Sensor, EV450, HE, LE, RD, P/N 131305 Duct Mount, CO2-D
IAQ Sensor, EV450, HE, LE, RD, P/N 131308 Room Mount, IAQ-W
IAQ Wiring Supplement (PDF) | PDF (1,023KB)
IAQ Sensor, EV450, HE, LE, RD, P/N 131307 Duct Mount, IAQ-D
IAQ Wiring Supplement (PDF) | PDF (1,023KB)
Occupancy Sensor, EV450, HE, LE, RD, P/N 131302 Ceiling Mount, MC-C
Occupancy Sensor, EV450, HE, LE, RD, P/N 131303 Wall Mount, MC-W
Smoke Detector, EV450, HE, LE, RD, P/N 102396 Duct Mount, SD-D
Remote Display, EV450, HE, LE, RD with Enhanced or Premium Controls, P/N 131311 Handheld/Wall Mount RD-M  
Room Pressure Sensor with Display, EV450, HE, LE, RD with Premium Controls, P/N 131314, RPS-WD  
Room Pressure Sensor without Display, EV450, HE, LE, RD with Premium Controls, P/N 131310, RPS-WOD  
Duct Static Pressure Sensor with Display, EV450, HE, LE, RD with Premium Controls, P/N 131315, DPS-WD  
Duct Static Pressure Sensor without Display, EV450, HE, LE, RD with Premium Controls, P/N 131309, DPS-WOD  
Temperature Sensor Kit, EV450, HE, LE, RD with Premium Controls for non-integrated heating, P/N 131318, TS  
Potentiometer Speed Control, EV450, HE1X-1.5X, P/N 147050 Remote Installed for ECM, SCECM
Filters
Filter, EV450, HE1.5, RD, HE-2XRTC, P/N 990080 Merv 8 14"x20"x2" Single Filter
Filter, EV450, HE1.5, RD, HE-2XRTC, P/N 990300 Merv 13 14"x20"x2" Single Filter
Filter, HE1.5, HE-4XRTC, P/N 990229 Merv 8 16"x20"x2" Single Filter
Filter, HE1.5, HE-4XRTC, P/N 990301 Merv 13 16"x20"x2" Single Filter
Heaters & Furnaces
EK Series Electric Duct Heaters

EH series heaters are no longer available effectively immediately. All attributes and capacities of EH Heaters will be available with EK series.

HE1.5XINV Standard
HE1.5XINV ECM
HE1.5XINV Bypass
HE1.5XINV CSI
HE1.5XINV | PDF (113KB)
HE1.5XINV | Word Doc (44KB)