Application Type:Indoor
Ventilation Type:Static plate, heat and humidity transfer
Typical Airflow Range:750-3,300 CFM
AHRI 1060 Certified Core:Three L125-G5
OA Filter(s):Total Qty. 3, MERV 8: 20" x 20" x 2"
RA Filter(s):Total Qty. 3, MERV 8: 20" x 20" x 2"
Dimensions:147 7/8" L x 90 1/8" W x 71 7/8" H
Weight:1700 - 3250 lbs. (varies by option)
Orientation
A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

V

Electrical Service
[33] 208V / 3 Phase / 60 Hz
[35] 230V / 3 Phase / 60 Hz
[34] 460V / 3 Phase / 60 Hz
[38] 575V / 3 Phase / 60 Hz
Fan Control
[E] ECM
[V] VFD
SA Fan Location
[B] Before Coil, Blow-thru (Standard)
[A] After Coil, Draw-thru
Vibration Isolation
[N] Neoprene Isolators (Standard)
[S] Spring Isolators
Controls
BACnet Factory Activation Available
Unit Fusing
[N] Non-fused (Standard)
[F] Fused
GFCI Convenience Outlet
Available
Recirculation Damper
Available
VRF Modification
Available
Cooling
[-] None
[C] Chilled Water Coil
[D] Direct Expansion Coil
[H] Heat Pump Coil
[P] Heat Pump & Hot Gas Reheat Coils
[R] Direct Expansion & Hot Gas Reheat Coils
Heating
[-] None
[E] Electric Heater
[G] Gas Heat Module
[P] Heat Pump Coil
[S] Steam Coil
[H] Hot Water Coil
Insulation
[1] 1" Insulation (Standard)
[2] 2" Insulation
Paint
2500 Hour Salt Spray
None (Standard)
Drain Overflow Switch
Available
Controls
Occupancy Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131302
Ceiling Mount, MC-C
Occupancy Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131303
Wall Mount, MC-W
CO2 Sensor, SL, EV Premium, HE, LE, RD, DN, P/N 131304
Wall Mount, CO2-W
CO2 Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131305
Duct Mount, CO2-D
IAQ Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131307
Duct Mount, IAQ-D
IAQ Sensor, SL, EV, EV Premium, HE, LE, RD, DN, P/N 131308
Wall Mount, IAQ-W
Room Temperature and Humidity Sensor, DN, P/N 102397
Wall Mount, RTH-W
Smoke Detector, HE, LE, RD, DN, P/N 102396
Duct Mount, SD-D
Remote Display, HE, LE, RD, DN, P/N 131311
Units with Enhanced or Premium Controls, Handheld/Wall Mount RD-M
Room Pressure Sensor, HE, LE, RD, DN, P/N 131314
Sensor with Display, Units with Premium Controls, RPS-WD 
Room Pressure Sensor, HE, LE, RD, DN, P/N 131310
Sensor without Display, Units with Premium Controls, RPS-WOD 
Duct Static Pressure Sensor, HE, LE, RD, DN, P/N 131315
Sensor with Display, Units with Premium Controls, DPS-WD 
Duct Static Pressure Sensor, HE, LE, RD, DN, P/N 131309
Sensor without Display, Units with Premium Controls, DPS-WOD 
Temperature Sensor Kit, HE, LE, RD, DN, P/N 131318
Units with Premium Controls for non-integrated heating, TS 
BACNet License Field Request, HE, LE, RD with Enhanced or Premium Controls, P/N 131316  
Filters
Filter, DN-3, P/N 990686
MERV 13 20"x20"x4" Single Filter
Filter, DN-3, P/N 990688
MERV 14 20"x20"x2" Single Filter
Filter, DN-3, P/N 990690
MERV 14 20"x20"x4" Single Filter
Filter, HE, CA, PA, RD, DN-3, P/N 990083
MERV 8 20"x20"x2" Single Filter
Filter, HE, CA, PA, RD, DN-3,  P/N 990084
MERV 8 20"x20"x2" Case of 12
Filter, HE, CA, PA, RD, DN-3, P/N 990303
MERV 13 20"x20"x2" Single Filter
Coil Accessories
Waterless Trap, DN, P/N 102387
Positive Pressure, WT-P
Waterless Trap, DN, P/N 102386
Negative Pressure, WT-N
DN Series CSI
DN-CSI-DOC | PDF (456KB)
DN-CSI-DOC | File (311KB)